| Nama Merek: | SSL |
| Nomor Model: | BC61063B |
| MOQ: | 1 |
| Waktu Pengiriman: | 20-55 hari |
| Ketentuan Pembayaran: | T/T |
30/90 MINUTES FIREPROOF LITHIUM-ION BATTERY SAFETY STORAGE CABINET
The Super Fireproof Lithium-Ion Battery Charging Cabinet is engineered to provide controlled, fire-resistant storage and charging for lithium-ion batteries in industrial environments. With 30- or 90-minute EN-rated fire resistance, an integrated self-closing fire protection system, and spill containment design, the cabinet significantly reduces the risks associated with battery thermal runaway, fire spread, and hazardous vapor release during charging operations.
This solution is purpose-built for facilities where lithium batteries are charged, stored, or staged daily and where compliance, safety, and operational continuity are critical.
| Specification | Description |
| Product Type | Lithium-Ion Battery Safety Storage & Charging Cabinet |
| Fire Resistance Rating | 30 minutes / 90 minutes (EN tested) |
| Cabinet Material | Powder-coated sheet steel |
| Structural Design | Multi-layer fire-resistant construction |
| Fire Sealing | Intumescent fire seals (expand under heat) |
| Door Design | Heavy-duty triple-hinged doors |
| Door Function | Manual close with automatic self-closing under fire |
| Self-Closing Trigger Temperature | 50°C / 122°F |
| Specification | Description |
| Top Ventilation Ports | 2 fire-rated ventilation openings |
| Valve Type | Butterfly valves |
| Automatic Closure Temperature | 70°C / 158°F |
| Exhaust Connection | DN 75 duct interface |
| Normal Operation | Allows connection to technical exhaust systems |
| Fire Condition | Ventilation and exhaust automatically seal to prevent oxygen supply |
| Specification | Description |
| Spill Containment | Liquid-tight spill sump |
| Sump Design | Removable sump with perforated insert |
| Safety Function | Captures battery leakage and prevents secondary fire risk |
| Internal Layout | Elevated storage to keep batteries dry |
| Mobility | Integrated transport base for upright in-house movement |
| Model | Volume (L) | Fire Rating | Doors | External Dimensions (mm) | Internal Dimensions (mm) | Net Weight (kg) |
| BC61063B | 350 | 90 min | 1 | 635 × 615 × 1950 | 555 × 555 × 1500 | 320 |
| BC61113B | 750 | 90 min | 2 | 1130 × 615 × 1950 | 1050 × 555 × 1500 | 508 |
With EN-tested 30- or 90-minute fire resistance, the Sopler lithium-ion battery charging cabinet provides a defined and measurable fire barrier. This fire rating is critical in battery charging areas, where thermal runaway can escalate rapidly and affect nearby equipment.
The cabinet doors remain operable during normal use but automatically self-close at 50°C (122°F) under fire conditions. Combined with intumescent fire seals, the system actively limits flame, heat, and smoke transmission without relying on manual intervention.
During normal charging, the cabinet supports vapor extraction through DN 75 exhaust connections. In fire conditions, the dual top ventilation ports automatically close at 70°C (158°F), cutting off oxygen flow and reducing fire intensity inside the cabinet.
Battery leakage during failure or overheating can create secondary ignition risks. The liquid-tight spill sump with perforated insert captures leaked electrolyte while keeping batteries elevated and dry, directly addressing this overlooked safety issue.
The powder-coated steel cabinet body, heavy-duty hinges, and integrated transport base allow the cabinet to withstand daily industrial handling while remaining compliant with fire safety requirements. Cabinets can be transported upright within facilities without compromising insulation integrity.
The Sopler Fireproof Lithium-Ion Battery Charging Cabinet combines certified fire resistance, automatic fire-response mechanisms, controlled ventilation, and spill containment into a single, purpose-built solution. By referencing measurable parameters—fire rating, closure temperatures, ventilation thresholds, and structural design—the cabinet delivers transparent, verifiable safety performance for modern lithium battery operations.